Cold storage sliding doors
Kavidoors sliding cold room doors are designed for refrigerated rooms (+0 °C), freezing rooms (-20 °C), and freezing tunnels (-40 °C) — ideal for controlled temperature environments. Available in commercial (Tecnik model) and industrial versions, they are perfect for large openings or elevated access points.
These doors feature a patented anti-tilt and anti-fall system and are CE Marked, ensuring high safety standards and durability for industrial refrigeration applications.
Gallery
Sliding doors for cold storage rooms
Kavidoors offers two models of sliding doors for cold storage rooms: the commercial model (Tecnik) and the industrial model. The industrial version is recommended for cold storage rooms and access areas requiring large-scale doors or overhead clearance. Meanwhile, the commercial model is ideal for any type of cold room located in retail environments.
These cold room sliding doors are equipped with a patented anti-tilt and anti-fall system, featuring a dual guiding mechanism developed by Kavidoors. They comply with CE Marking standards, meeting essential product safety requirements related to the prevention of occupational hazards.


Advantages of sliding doors for storage room
- Simple installation and low maintenance. Supplied pre-assembled.
- Durable and resistant mechanical components.
- Precision adjustment with 4-point alignment.
- Self-supporting frame for 40 mm thickness.
- Suitable for the food industry.
- Insulated with PUR foam.
- Excellent fire performance.
- Outstanding functional, climatic, hygienic, and sanitary characteristics.
Guide anti-fall & anti-tilt safety system
This system consists of a dual safety guiding mechanism that enables smooth opening and closing of sliding components. It is designed to withstand heavy structural loads, ensuring maximum safety by preventing the door from being easily removed or released while in motion or at rest, thanks to its robust technical features and design.


Learn more about the anti-fall system
Sliding cold room door models

Kit sliding cold room doors
This model is supplied as a disassembled kit, ideal for modular cold rooms without a panel. It facilitates easier handling and transport for on-site assembly. Designed for use with 100 mm thick smooth sandwich panels, it is suitable for operating temperatures from +0ºC to -20ºC.
Prepared for left- or right-hand opening. The full kit or individual components can be supplied:
- Guide kit
- Frame kit
- Leaf kit
Double-leaf sliding cold doors for storage room
When there is insufficient space in the cold room for a single-leaf sliding door or faster access is needed, the double-leaf sliding cold room door is the ideal solution. Specifically designed for negative temperature environments, it is suitable for preservation rooms (0 ºC), freezers (-20 ºC), and freezing tunnels (-40 ºC). This model is also equipped with the anti-tilt and anti-fall safety system.

Any questions? Get in touch with us
FAQs about about sliding cold storage doors
-
Which sliding cold room door do I need?
The choice depends on the temperature, opening dimensions, temperature difference and opening frequency. For cold rooms at 0 °C, doors designed for positive temperatures are suitable; at −20 °C, greater insulation and a negative-temperature configuration are required. For freezing tunnels down to −40 °C, an industrial door specifically designed for intensive cold must be used. Kavidoors offers Tecnik models for 0 °C and −20 °C and industrial models for temperatures down to −40 °C.
-
Which sliding cold room door model do I need?
The Tecnik model is mainly designed for commercial cold rooms and openings up to 2,500 × 3,000 mm, with operating temperatures of 0 °C and −20 °C and door leaves 80 or 100 mm thick. The Industrial model is recommended for larger openings, demanding working conditions and temperatures down to −40 °C, with 100, 120 or 140 mm thick leaves. Temperature, traffic, leaf weight, opening system and installation conditions must also be assessed.
-
What thickness should the door leaf have?
The thickness must be selected according to the internal and external temperatures and the temperature difference. Kavidoors offers 80 and 100 mm leaves for Tecnik and 100, 120 and 140 mm for Industrial. In general, the lower the room temperature and the greater the temperature difference, the greater the insulation required. Humidity, outdoor exposure, opening frequency and climate must also be considered. Kavidoors can carry out a thermal study to determine the appropriate configuration.
-
What are the maximum dimensions and is it made to measure?
Yes. Sliding cold room doors are manufactured to measure according to the opening dimensions and operating conditions. Tecnik is available for openings up to 2,500 mm wide and 3,000 mm high. For larger dimensions, large industrial openings or high-level passages, the Industrial model should be considered. The leaf weight, available sliding space, support strength and suitability of a single- or double-leaf configuration must also be checked.
-
When should I choose one or two door leaves?
A single leaf is usually suitable when there is enough lateral space to move it completely clear of the opening. Two leaves may be more suitable when lateral clearance is limited on one side or when a shorter opening time is required, as both leaves move in opposite directions and each travels a shorter distance. This configuration can be used at 0 °C, −20 °C and down to −40 °C, and can incorporate the Kavidoors anti-drop and anti-tip safety system.
-
Is a manual or automatic cold room door better?
The choice depends mainly on usage frequency, door dimensions and traffic type. A manual door may be sufficient for cold rooms with few daily openings, moderate dimensions and mainly pedestrian traffic. Automation is recommended when there is frequent movement of operators, trolleys, pallet trucks or forklifts. It allows the door to open before the vehicle arrives and close automatically after passage, streamlining traffic and reducing the time the cold room remains open.
-
How much does an industrial sliding cold room door cost?
The price depends on the opening dimensions, operating temperature, door leaf thickness, finish, number of leaves and opening system. The automation, heated elements for low temperatures, safety devices, impact protection, frame type and installation conditions also affect the quotation. There is therefore no single price applicable to every door. To prepare an accurate quotation, the characteristics of the cold room and opening, together with the operational requirements, must be known.
-
How much space does a sliding cold room door need?
Sufficient lateral space is required for the leaf to move completely clear of the opening, depending on the door width, guide system and automation. There must also be enough space above the opening for the guide, supports and, where applicable, the motorisation. The floor, wall or panel must be level and provide sufficient strength. If lateral clearance is limited, a double-leaf solution can be considered; if there is no lateral space but sufficient vertical clearance, a vertical or guillotine cold room door may be more suitable.
-
What insulation, sealing and safety should it have?
The door leaf must have suitable insulation for the temperature and temperature difference, while maintaining sufficient closing pressure against the perimeter seals to limit air infiltration, condensation and ice formation. In freezing rooms or tunnels, heated elements may be required to prevent the seals or frame from being blocked by ice. Kavidoors sliding cold room doors incorporate a patented dual-guide anti-drop and anti-tip system designed to withstand high structural loads. The doors also comply with applicable CE marking requirements.
-
What information is needed to request a door quotation?
It is advisable to provide the opening width and height, internal and external temperatures, panel type and thickness, available lateral and upper space, cold room type, traffic, opening frequency, manual or automatic operation, sliding direction, humidity and cleaning conditions, required finish or colour, photographs of the opening and installation area, and the installation town and country. With this information, the technical team can determine whether Tecnik or Industrial is appropriate, select the leaf thickness, define the opening system and check whether one or two leaves can be installed.