Horizontal sliding fire-rated doors
Kavidoors’ RF horizontal sliding fire-rated doors provide effective fire protection, with fire resistance ratings of 60, 90, and 120 minutes. They are normally kept open by an electromagnet until a fire detection signal or power failure activates the counterweight system, causing the door to close automatically. Thanks to their advanced design, these doors ensure reliable automatic closing in the event of a fire or power outage, providing continuous safety and operational reliability in demanding industrial environments.

Gallery
Structure of the RF sliding fire door
The door consists of individual slats based on a steel frame structure. The slats are covered with fire-resistant material and metal sheeting. Door leaf stability is achieved by reinforcing the panels with steel profiles connected by threaded rods. The slats are suspended from a guide rail; each slat is equipped with a separate roller carriage. RF sliding fire doors can be closed either by a counterweight system or by gravity. Guaranteed mechanical durability: 50,000 operating cycles (for electrically operated doors).


Types of fire-resistant sliding doors
- Single-leaf: The door consists of one integral leaf that slides either to the left or to the right.
- Double-leaf: The door is divided into two parts (either symmetrical or asymmetrical), with each leaf sliding to opposite sides of the opening.
- Telescopic: Each leaf is composed of 2–3 sections that slide telescopically behind each other, either to the left or right. This solution reduces the amount of space needed when the door is open.
- Manual or automatic: In automatic versions, opening and closing times can be individually adjusted.
Additional features
The RF sliding door can be supplied with an emergency exit door, available with or without a threshold, and can be equipped according to specific requirements. They can be mounted on concrete, brick, clay tile, silicate walls, or steel structures, ensuring the required fire resistance. Our fire-resistant sliding doors are custom-made in accordance with European standards.
They are approved by the Building Research Institute:
- Certificate No. AT-15-8452/2013
They also hold the PZH Certificate:
- No. HK/B/0998/01/2013
These doors are suitable for use in Ex Zones 1 and 2, in compliance with:
- Directive 94/9/EC
- EN 1127-1:2007
- EN 13463-1:2009
- EN 13463-5:2011
- TR/CLC 50404:2003


Download our catalog
Download our technical catalogue now and discover how we can optimize your operations with high-quality, efficient products.
Automation and safety
Fire-resistant sliding doors can be fully automated, ensuring efficient and safe closing in case of emergencies.
The electromagnetic retention system keeps the door open until a fire signal activates the counterweight, enabling an airtight seal to prevent fire spread.
This improves workplace safety, guaranteeing a fast and effective response to critical situations.

Quick and versatile installation
Installation is fast and efficient, without the need for ceiling anchoring, allowing easy adaptation to various types of openings and structures.
Their versatile design ensures seamless integration into different industrial environments. Doors are customizable in terms of colors and dimensions, meeting specific project requirements while ensuring optimal fire protection.
Durability and reliability
Designed to withstand over 50,000 operating cycles, RF sliding fire doors guarantee exceptional durability and reliability. Custom-made, Kavidoors RF sliding fire doors comply with the most stringent safety regulations, providing optimal protection in industries such as food processing, distribution, and transportation.
Their fire resistance and long-term reliability make them a trusted and efficient choice for improving workplace safety and minimizing operational risks.
Any questions? Get in touch with us
FAQs about fire-resistant sliding doors
-
What fire resistance do I need: 60, 90, 120 or 180 minutes?
The required resistance depends on the building use, door location, planned fire compartmentation and project requirements. Kavidoors offers sliding fire doors with 60, 90, 120 and 180 minutes of fire resistance. The final classification must be determined by the responsible technical professional in accordance with the regulations applicable in the country of installation.
-
Do I need a single-leaf or double-leaf sliding fire door?
A single-leaf door is suitable when there is enough lateral space to fully accommodate the leaf when open. A double-leaf configuration is useful for wide openings or when the travel is to be distributed towards both sides. The opening width, available space and certified door configuration must be considered when selecting the appropriate solution.
-
What maximum dimensions are possible, and is it made to measure?
Yes. Kavidoors sliding fire doors are manufactured to measure within the limits established by their classification, test results and technical documentation. Permitted dimensions depend on the fire resistance, number of leaves, total assembly weight, guiding system and support characteristics. Each opening must therefore be assessed before defining the door configuration.
-
How much lateral and upper space is needed for installation?
The door requires sufficient lateral space to accommodate the leaf or leaves when open. Space must also be reserved above the opening for the guide, hangers, supports and closing system. Where lateral travel is limited, a double-leaf or telescopic configuration may be considered. Kavidoors doors do not require ceiling anchors, but suitable lateral and upper supports are required to secure the assembly.
-
Can it stay open and close automatically in a fire?
Yes. During normal operation, the door can remain open using an electromagnetic hold-open system. When a fire is detected or the power supply fails, the electromagnet releases the door and the counterweight system causes it to close automatically, restoring the building’s fire compartmentation and helping prevent fire from spreading between compartments.
-
Does the door also limit smoke passage?
Fire resistance and smoke control are different performance characteristics. Kavidoors sliding fire doors can optionally be supplied in a configuration resistant to smoke passage. When the project requires smoke control, this must be specified when requesting a quotation so that the applicable classification and the necessary sealing elements can be checked.
-
Can it include a pedestrian door for evacuation?
Yes. Kavidoors sliding fire doors can be supplied with an integrated emergency exit door, with or without a threshold and equipped according to the project requirements. Its use as an evacuation route must be verified in accordance with the applicable regulations and certified configuration, including the hardware, opening direction and emergency devices.
-
What regulations and certification must the door meet?
The door must have a valid classification for the complete assembly, including the leaf, frame, guide, hardware, closing system and accessories. Required documentation and marking depend on the country of installation. In Europe, the requirements applicable to fire-resistant and smoke-control doors and the relevant product standards must be checked. Kavidoors manufactures each configuration in accordance with the applicable standards and approvals.
-
How much does it cost and what is the supply lead time?
The price depends on fire resistance, dimensions, number of leaves, manual or automatic operation, electromagnetic hold-open system, accessories, finish and installation conditions. The supply lead time also varies according to the level of customisation and required certified configuration. To provide an accurate price and lead time, the specific characteristics of the project must first be reviewed.
-
What information do I need to request a quotation?
To prepare a quotation, it is advisable to provide the opening width and height, required fire resistance, door type, lateral and upper clearance, wall type, material and thickness, closing direction, operation, smoke control, pedestrian door, fire detection system, finish or colour, installation country and location, plus photographs and drawings. With this information, Kavidoors can assess feasibility, select a certified configuration and prepare a project-specific quotation.
-
How do I choose the right sliding fire door?
To choose the appropriate configuration, it is advisable to provide the opening dimensions, required fire resistance, available space and support characteristics. Kavidoors’ technical team can assess the access, review the compartmentation requirements, check installation feasibility and recommend a certified configuration designed to maintain the building’s fire compartmentation and installation safety.